ENTER/EXIT PROGRAMMING MODE I 2 of 5 Set Length 2
Product Reference Guide 145
I 2 of 5 Set Length 2
This feature specifies one of the barcode lengths for I 2 of 5 Length Control. Length 2 is the
maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length
Mode. The length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 s
pecifies to ignore this length (only
one fixed length).
Table 9 provides examples for setting Length 2. See page 243 for detailed instructions on setting
this feature.
Table 9. I 2 of 5 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
Ignore This
Length
4 Characters 14 Characters 50 Characters
2
Pad with leading zeroes to
yield tw
o digits
00 04 14 50
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT I 2 OF 5 LENGTH 2 SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘4’ ‘1’ and ‘4’ ‘5’ AND ‘0’
6 Scan ENTER/EXIT PROGRAMMING MODE
Select I 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not
sav
e the entry string. You can then start again at the begin-
ning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters